Megger PAT320 PAT Tester - Business in a Box Kit
Megger PAT320 Technical Specifications
上海麒诺机电科技有限公司欢迎随时来电咨询!谢谢
Electrical Supply Range
230V AC
230V AC ±10%
110V AC
110V AC ±10%
Supply Measurement
Voltage
±2% ± 1V
Frequency
±1% ± 0.1Hz
Bond Test
Open Circuit Voltage
9V AC ±10% ±0.1V (Supply: 230V 50Hz)
10A Bond Test Current
10A rms ±20% ±0.5A into 0.1Ω
25A Bond Test Current
25A rms ± 5% ± 0.5A into 0.1Ω
Earth Bond Resistance Accuracy
±5% ± 3 digits (0 to 0.49Ω)
±5% ± 5 digits (0.5 to .99Ω)
Earth Bond Resistance Resolution
10mΩ (0 to 1.99Ω)
Display Range
0 to 1.99Ω
Bond Test Nulling
Up to 1.00Ω
Adjustable Test Duration
User selectable from 1 sec to 20 sec
Continuity Test
Note
The continuity test is a DC test performed automatically
in both positive and negative directions. The average of
the two results is shown
Continuity Test Voltage
4.0V DC -0% +10% (open circuit)
Continuity Test Current
200mA -0% + 10% ± 5mA (into 2Ω load)
Continuity Resistance Accuracy
±5% ±3 digits (0 to 0.49Ω)
±5% ±5 digits (0.5 to .99Ω)
Continuity Resistance Resolution
10mΩ (1 to 19.99Ω)
Display Range
0 to 19.99Ω
Continuity Test Nulling
Up to 9.99Ω
Test Duration
User selectable from 1 sec to 20 sec
Insulation Test
Insulation Test Voltage
250V DC -0%/+25% open circuit
500V DC -0%/+25% open circuit
(500V DC across 0.5MΩ)
Insulation Resistance Accuracy (230V)
±2% ±5 digits (0 to 19.99MΩ)
±5% ± 10 digits (20 to 99.99MΩ)
Insulation Resistance Accuracy (110V)
±5 ±5 digits (0 to 10MΩ)
Insulation Resistance Resolution
0.01MΩ (0.10 to 99.99MΩ)
Display Range
0 to 99.99MΩ
Test Duration
User selectable from 1 sec to 1 minutes
Substitute Leakage Test
Test Voltage
40V AC ±10%
Test Frequency
Nominal mains 50/60Hz
Leakage Current Accuracy
±5% ± 5 digits
Leakage Current Resolution
0.01mA
Display Range
0 to 19.99mA
Test Duration
User selectable from 1 sec to 1 minute
Reading corrected to 230V + 10% or 110V +10% AC
Differential Leakage Current
Test Voltage
Nominal mains 110V/230V AC
Test Frequency
Nominal mains 50/60Hz
Differential Leakage Current Accuracy
±5% ± 5 digits
Differential Leakage Current Resolution
0.01mA
Display Range
0 to 19.99mA
Reading corrected to 230V +10 % or 110V + 10% AC
Touch Current Test
Test Voltage
Nominal mains 1150/230V AC
Test Frequency
Nominal mains 50/60Hz
Touch Current Accuracy
±5% ±5 digits
Touch Current Resolution
0.01mA
Display Range
0 to 10mA
Test Duration
User selectable from 1 sec to 5 sec
Reading corrected to 230V + 10% or 110V + 10% AC
Operational Test
Test Voltage
Nominal mains 110V/230V AC
Accuracy
±5% ±10 digits (0 to 99VA)
±5% ±50 digits (100 to 999VA)
±5% ±100 digits (1000 to 3700VA)
Resolution
1VA (0 to 3700VA)
Display Range
0 to 3.99KVA
Reading corrected to 230V or 110V AC
Results show load VA
Extension Lead Test
Polartity Test Voltage
12V
Polarity
Leak OK
Live neutral S/C
Live neutral reversed
Live/neutral O/C
Portable RCD Test
RCD Test Voltage
Nominal mains 110/230V
RCD Test Frequency
50Hz
Test Current Accuracy
-8% to -2% (1/2 x I)
±2% to +8^ (1 x 1,5 x I)
Trip Time Accuracy
±1% ±5 digits
Trip Time Resolution
0.1ms
Display Range
0 to 1999ms (1/2 x I)
0 to 300ms (1 x I)
0 to 40ms (5 x I)
Fuse Test
Test Voltage
3.3V
Warning
Audible Beep if fuse is ok